Research Article
Combined Data with Particle Swarm Optimization for Structural Damage Detection
Table 4
Comparison of damage detection results of case one by ARSAGA and IEPSO.
| Element no. | Stiffness damage factors | Exact | ARSAGA | IEPSO |
| 1 | 1.0 | 0.963 (−3.7%) | 1.0 | 2 | 0.9 | 0.914 | 0.9 | 3 | 1.0 | 1.0 | 1.0 | 4 | 1.0 | 0.984 | 0.999 | 5 | 1.0 | 0.992 | 1.0 | 6 | 1.0 | 1.0 | 1.0 | 7 | 1.0 | 1.0 | 1.0 | 8 | 1.0 | 0.978 | 0.999 | 9 | 0.9 | 0.905 | 0.901 | 10 | 1.0 | 1.0 | 1.0 | 11 | 1.0 | 1.0 | 1.0 | 12 | 1.0 | 0.987 | 1.0 | 13 | 1.0 | 1.0 | 1.0 | 14 | 1.0 | 0.991 | 1.0 | 15 | 1.0 | 1.0 | 1.0 | 16 | 0.85 | 0.852 | 0.851 (0.12%) | 17 | 1.0 | 1.0 | 1.0 | 18 | 1.0 | 1.0 | 0.999 | 19 | 1.0 | 1.0 | 1.0 | 20 | 1.0 | 1.0 | 1.0 |
|
|