Abstract

Thickness of tundish cover flux (TCF) plays an important role in continuous casting (CC) steelmaking process. Traditional measurement method of TCF thickness is single/double wire methods, which have several problems such as personal security, easily affected by operators, and poor repeatability. To solve all these problems, in this paper, we specifically designed and built an instrumentation and presented a novel method to measure the TCF thickness. The instrumentation was composed of a measurement bar, a mechanical device, a high-definition industrial camera, a Siemens S7-200 programmable logic controller (PLC), and a computer. Our measurement method was based on the computer vision algorithms, including image denoising method, monocular range measurement method, scale invariant feature transform (SIFT), and image gray gradient detection method. Using the present instrumentation and method, images in the CC tundish can be collected by camera and transferred to computer to do imaging processing. Experiments showed that our instrumentation and method worked well at scene of steel plants, can accurately measure the thickness of TCF, and overcome the disadvantages of traditional measurement methods, or even replace the traditional ones.

1. Introduction

As the development of high-speed casting, tundish cover flux (TCF) is becoming the key material for continuous casting process, which has more and more important and irreplaceable roles on the quality of steel billet. The main functions of TCF are as follows: isolate the steel surface to prevent freezing, protect the steel surface from oxidation, absorb inclusions that are transported to the surface, maintain a low friction between steel shell and mold by lubrication, create an optimum heat transfer from steel to mold, and so on [14].

The melting point of TCF (about 1000~1150°C) is lower than the temperature of molten steel (about 1500°C). And the TCF is divided into three main parts according to the physical form, namely, liquid slag layer, sintered layer, and powder slag layer (shown in Figure 1). TCF is added on the top of the molten steel in the continuous casting mold, which partially melts and forms a liquid slag layer (about 6~15 mm) above the molten steel. The liquid slag layer can partly prevent the heat of molten steel from transferring; therefore, above the liquid slag layer, temperature drops, which forms a sintered layer (about 600~900°C). Above the sintered layer, more heat is prevented; therefore, the TCF can keep its original pulverous characteristic to form a powder slag layer. The powder slag layer covers the molten steel surface evenly to prevent heat radiation and isolate oxygen.

In the continuous casting steelmaking process, due to crystallizer vibration and solidified shell movement, the liquid slag layer may slowly get into the gap between the shell and the copper wall of crystallizer. Therefore, along with the casting process, the liquid slag layer is constantly consumed by the molten steel and gets supplement from the sintered layer. Similarly, the sintered layer is constantly transformed into liquid slag layer and gets supplement from the powder slag layer. And the operator keeps an eye on the powder slag layer and adds new TCF into CC tundish as necessary. The thickness of TCF has a great effect on the continuous casting steelmaking process; if the TCF is too thin, the steel will become carburized, unmelted slag patches will occur as surface defects, and worse of all the result can be a breakout because of too high friction between steel shell and mould. On the contrary, if the TCF is too thick, crystallized rim will emerge at the meniscus which will disturb the solidification process and cause surface defects on the steel. Therefore, TCF thickness is an essential parameter to guarantee the quality of strand surface and can provide important information for the operators to keep track of the status in the CC tundish.

Nowadays, in continuous casting steelmaking process, the most common used measurement methods for TCF thickness are single-wire measurement method and double-wire measurement method, because these two methods are cheap and easily operated. In single-wire measurement method, one iron wire is vertically inserted into the molten steel, and kept steady for 3~5 seconds. Then pull it out and measure the TCF thickness based on the length of color change and slag-adhering part (shown in Figure 2). In double-wire measurement method, one iron wire and one copper wire, which have the same length, are parallel and firmly tied together, then vertically inserted into the molten steel, and kept steady for 3~5 seconds. Melting point of the iron wire is higher than the temperature of liquid slag layer and lower than the temperature of the molten steel, therefore, the iron wire below the liquid slag layer is melted. Melting point of the copper wire is higher than the temperature of sintered layer and lower than the temperature of liquid slag layer; therefore, the copper wire below the sintered layer is melted. The whole thickness of TCF can be calculated based on the length of the color change and slag-adhering part on the iron wire. Compared with the singe-wire measurement method, the double-wire measurement method can specifically measure the thickness of the liquid slag layer using the length of the remaining iron wire minus the length of the remaining copper wire (shown in Figure 3). Although the single-wire measurement method and the double-wire measurement method are widely used in continuous casting steelmaking process, they both have insurmountable and severe shortcomings: operators need to stand on the tundish to hold the wires, which means lethal danger to operators; the detection results are easily influenced by the operators, such as hand trembling or not vertically holding the wires; poor repeatability. All these shortcomings make these two TCF thickness measurement methods inaccurate and dangerous.

In this paper, a novel TCF thickness measurement method and instrumentation are proposed. We use a high-definition industrial camera to collect the image information in the CC tundish, which is fastened to a custom-designed mechanical device. The thickness of TCF is calculated based on the computer vision algorithms, including image denoise method, monocular range measurement method, scale invariant feature transform (SIFT), and image gray gradient detection method. Our measurement method is noncontact measurement, full automatic working, good repetitiveness, and absolutely safe.

2. Method

The TCF thickness measurement method and instrumentation are an extension of a previous work from our group [521], which is continuous temperature measurement method and sensor for molten steel in CC tundish based on blackbody chamber theorem. We briefly recall it in order to make the following sections more clearly.

Theoretical principle of continuous temperature measurement method is blackbody radiation theorem: represented the spectral radiosity of blackbody chamber, represented the spectral emissivity of blackbody chamber, represented the brightness temperature of blackbody chamber, and represented the actual temperature of blackbody chamber.

Based on this theorem, we specifically made a measurement bar and used it as a temperature sensor, which was inserted into the molten steel to measure the temperature of molten steel. The measurement bar was the core component of the system, which was composed of external tube and internal tube. The external tube was heat resistant, shock resistant, and anti corrosion and had good heat conduction, which can offer protection for the internal tube. The internal tube was made of certain translucent medium, which had steady radiation characteristic and specular/diffusion reflection characteristic. Heat radiation in the measurement bar was transformed into electrical signal by a photoelectric transducer. And the electrical signal can be used to calculate the temperature of the molten steel based on the blackbody radiation theorem. The schematic diagram of the system was shown in Figure 4.

More details about the continuous temperature method and sensor for molten steel in CC tundish can be referenced from [513].

2.1. Theory

The measurement bar is also the core component of  TCF thickness measurement method and instrumentation. While the measurement bar is inserted into the molten steel, a high-definition industrial camera is used to collect the image information in the tundish. Based on computer vision algorithms, which are elaborated in the Sections 2.3 and 2.4, TCF thickness is calculated by where represents the distance from TCF lower surface to optical center of the camera and represents the distance from TCF upper surface to optical center of the camera (shown in Figure 5).

Molten steel and TCF have different thermal conductivities; therefore, these two different media have different temperatures, and there is obvious temperature gradient in the interface layer of these two media. While the measurement bar is inserted into the molten steel for long enough time (shown in Figure 5), the measurement bar can be in the state of thermal balance. And then the measurement bar is pulled up; the temperature information of molten steel and TCF can be reflected by the luminance of the measurement bar (shown in Figure 6). In Figure 6(a), the brighter zone indicates that this part of the measurement bar is in the molten steel before being pulled up, and the darker zone indicates that this part of the measurement bar is in the TCF before being pulled up. The arrow indicates the peak value of image gradient between the brighter zone and the darker zone, which is also the interface layer between the molten steel and the TCF. In Figure 6(b), it can be seen that the temperature on the measurement bar has an intense change, which causes the peak value of the temperature gradient indicated by the arrow. These two arrows in both Figures 6(a) and 6(b) actually point to the same location of the measurement bar, which is the lower surface of the TCF. Therefore, the distance from TCF lower surface to optical center of the camera can be calculated by gray gradient detection in the image, which is elaborated in Section 2.4.

2.2. Instrumentation

As mentioned before, the measurement bar is inserted into the molten steel; therefore, a specialized mechanical device is required to hold the measurement bar, and the camera is also fixed on the mechanical device (shown in Figure 7). The mechanical device can ascend and descend under the control of frequency conversion motor, and the measurement bar can be lifted and lowered with the movement of the mechanical device. The camera is fixed and well-secured on the crossbeam of the mechanical device, and in case of overheating, the camera is cooled down by cool air through ventilating pipe. With the help of this mechanical device, the height of the crossbeam, the temperature of the measurement bar, and images collected by the camera are transferred to the computer and the programmable logic controller (PLC, Siemens S7-200). We can use all these information to make judgments and calculate TCF thickness. The main functions of the computer are imaging processing and displaying the calculation result of TCF thickness. The main functions of the PLC are controlling the movement of the mechanical device and making it accurate and steady. The schematic diagram of the whole instrumentation system is shown in Figure 8.

2.3. TCF Upper Surface Distance Measurement

The distance from TCF upper surface to the optical center of camera is calculated based on the principle of monocular distance measurement [22, 23]. Two images ,   can be obtained while the camera is moved from position to position . In these two images, the same objects have different coordinates due to the camera movement. According to the coordinate differences and the movement distance from to , the distance from the objects to the optical center of camera can be calculated. And there are two key steps in the calculation: the transformation from image coordinates to the world coordinates; matching the corresponding pixels of the same objects in two images and .

2.3.1. Transformation from the Image Coordinates to the World Coordinates

Suppose that the image coordinates are defined as , and the world coordinates are defined as . We can see that the image coordinates are two-dimensional and the world coordinates are three-dimensional; therefore, one of the world coordinates should be set as constant. The base point of the image coordinate system is defined as the center of the image (shown in Figure 9). The base point of the world coordinate system is defined as the intersection point of TCF upper surface and the optical axis originated from the camera’s optical center (shown in Figure 10); therefore, . The transformation from image coordinates to the world coordinates is defined as formula (3), and the details of proof can be obtained in appendix.

In Figure 10, plane ABU represents TCF upper surface, ABCD represents the camera’s field of view, point represents the camera’s optical center, line OG represents the camera’s optical axis, point represents the intersection point of optical axis and plane ABU, point is also the base point of the world coordinate system, point represents the projection point of optical center on the plane ABU, and the distance from point to point is h. X-G-Y represents the rectangular coordinate system. represents the camera’s vertical field angle, represents the camera’s horizontal field angle, and represents the camera’s pitch angle. Namely, , line OG equally divides ; , line OG equally divides ,  . Point is any point on the TCF upper surface, and its world coordinate is in the rectangular coordinate system X-G-Y. From point P, draw perpendicular line on the axis , and the perpendicular foot is point Q; therefore, . Connect point and point U, and line PU intersects axis GX at point L; therefore, . Connect point and optical center O, and the intersection angle of line OL and optical axis is β. Connect point and optical center O, and the intersection angle of line OQ and optical axis is α: H represents the height of the image, W represents the width of the image, h represents the vertical distance from camera’s optical center to the TCF upper surface, represents the camera’s vertical field angle, represents the camera’s horizontal field angle, and represents the camera’s pitch angle.

Based on formula (3), the world coordinates of any point on the TCF upper surface can be calculated, and the only unknown parameter is h, which is the distance from the TCF upper surface to the camera’s optical center. By moving the camera vertically from to , although and are unknown, can be obtained (shown in Figure 11). Suppose that the same object on the TCF upper surface has one world coordinate before movement and another world coordinate after movement. While the camera is moved from to , then the camera’s optical center is moved from to after movement; therefore, the base point of world rectangular coordinate system is also moved from to . Because the movement of camera is vertical, two world rectangular coordinate systems have the same -axis and different -axis; therefore, and have the same horizontal coordinates in the world coordinate system, namely, . Therefore, the distance from TCF upper surface to camera optical center can be calculated by formula (4):

2.3.2. Matching the Corresponding Pixels of the Same Objects in Two Images

SIFT based image registration method is used to match the corresponding pixels of the same objects in two images. SIFT was published by Lowe in 1999 [24] and improved in 2004 [25], which was used to detect and describe local image features. SIFT is an excellent feature descriptor, because it is invariant to uniform scaling, orientation, and partially invariant to affine distortion and illumination changes. SIFT’s application includes object recognition, robotic mapping and navigation, image stitching, 3D modeling, gesture recognition, video tracking, individual identification of wildlife, and match moving.

Scale space is a formal theory for handling image structures at different scales from physical and biological vision, by representing an image as a one-parameter family of smoothed images. The main type of scale-space is the linear (Gaussian) scale-space, which can be defined by represents one image, * represents convolution, and represents Gaussian filter function: represents image coordinates, and σ represents scale level. Therefore, difference of Gaussian (DoG) scale space can be defined as

Once DoG images have been obtained, keypoints are identified as local minima/maxima of the DoG images across scales. This is done by comparing each pixel in the DoG images to its eight neighbors at the same scale and nine corresponding neighboring pixels in each of the neighboring scales. If the pixel value is the maximum or minimum among all compared pixels, it is selected as a candidate keypoint.

Scale-space extreme detection produces too many keypoint candidates, some of which are unstable. The next step in the algorithm is to perform a detailed fit to the nearby data for accurate location, scale, and ratio of principal curvatures. This information allows points to be rejected that have low contrast (and are therefore sensitive to noise) or are poorly localized along an edge.

The interpolation of  keypoints is done using the quadratic Taylor expansion of the DoG scale-space function:

Then, the location of the extreme   is determined by taking the derivative of this function with respect to and setting it to zero:

The DoG function will have strong responses along edges, even if the candidate keypoint is not robust to small amounts of noise. Therefore, in order to increase stability, the Hessian matrix is used to eliminate the keypoints that have poorly determined locations but have high edge responses: α represents bigger eigenvalue, and β represents smaller eigenvalue. Suppose that . We can get

It follows that, for some threshold eigenvalue ratio , if for a candidate keypoint is larger than , that keypoint is poorly localized and hence rejected.

Each keypoint is assigned one or more orientations based on local image gradient directions. This is the key step in achieving invariance to rotation as the keypoint descriptor can be represented relative to this orientation and therefore achieve invariance to image rotation: represents the gradient magnitude, and represents the orientation.

A set of orientation histograms are created on pixel neighborhoods with 8 bins each. These histograms are computed from magnitude and orientation values of samples in a region around the keypoint such that each histogram contains samples from a subregion of the original neighborhood region. The magnitudes are further weighted by a Gaussian function with σ equal to one half the width of the descriptor window. The descriptor then becomes a vector of all the values of these histograms. Since there are histograms each with 8 bins, the vector has 128 elements. This vector is then normalized to unit length in order to enhance invariance to affine changes in illumination.

The SIFT feature descriptors extracted from two images , while the camera is moved from position to position are shown in Figure 12.

2.4. TCF Lower Surface Distance Measurement

While the measurement bar is pulled out, due to the temperature difference, there is temperature gradient on the measurement bar. And the temperature gradient is reflected as gray gradient in the image (shown in Figure 6). Therefore, the distance from TCF lower surface to the camera optical center is calculated based on gray gradient detection in the image.

The measurement bar and the camera are both fixed in the mechanical device, so they are in the relatively static state. Therefore, in the image, pixels in the middle line of measurement bar have constant distance to the camera optical center. Suppose that () represents pixel coordinate and represents the pixel’s distance to camera optical center. The function can be obtained (shown in Figure 13).

There is a pitch angle between camera optical axis and the middle line of the measurement bar (21.5° in this paper); therefore, pixels in the middle line of the measurement bar have different spatial resolutions (mm/pixel), and the bigger the vertical coordinate is, the higher the spatial resolution is. Suppose that () represents pixel coordinate, and sr represents the pixel’s spatial resolution, the function can be obtained (shown in Figure 14).

In the continuous casting steelmaking process, the range of the TCF thickness is 5 mm~50 mm. Given the prior knowledge, the functions and g, and the distance from the TCF upper surface to the optical center, the image region of interest (ROI) on the measurement bar can be obtained. And in the ROI, the Gaussian-Laplace operator is used to detect the gray gradient (shown in Figure 15). While the gray gradient caused by TCF lower surface is detected, distance from TCF lower surface to camera optical center can be obtained by using function f.

2.5. Implementation

The steps below outline the procedure for measuring the thickness of TCF, and the Steps are circularly implemented every 30 minutes.

(1)  Initialization. Prepare the mechanical device, move it to the specified location, check the status of the movement bar and the camera, and ensure that they are steadily fixed. Then control the mechanical device to insert the movement bar in the molten steel.

(2)  Thermal Balance. Keep the movement bar in the molten steel long enough to make it in the thermal balance (30 minutes in this paper). And save the current position as and current image as .

(3)  Pulling out the Measurement Bar. Control the mechanical device to pull out the measurement bar, and save the current position as and current image as .

(4)  Distance Calculation from TCF Upper Surface to Camera Optical Center. Use formula (4) to calculate the distance from TCF upper surface to camera optical center, and save it as .

(5)  Distance Calculation from TCF Lower Surface to Camera Optical Center. Use the Gaussian-Laplace operator to obtain the image gray gradient caused by TCF lower surface, and use the function to calculate the distance from TCF lower surface to camera optical center, and save it as .

(6)  TCF Thickness Calculation. Use formula (2) to calculate the TCF thickness.

(7)  End Measurement. Control the mechanical device to insert the measurement bar in the molten steel, and then implement Step .

3. Experiments and Results

The TCF thickness measurement instrumentation has already been installed and applied in four Chinese steel plants, which are Nanjing Steel Plant located in Jiangsu province since 2010, Daye Steel Plant located in Hubei province since 2011, Hanzhou Steel Plant located in Zhejiang province since 2011, and Sanming Steel Plant located in Fujian province since 2012. The instrumentation works well in these four worksites, and Figure 16 shows the working condition at scene.

3.1. Experiment of TCF Upper Surface Distance Measurement

We did this experiment to verify the correctness and accuracy of the method discussed in Section 2.3. The experiment steps are as follows (1) We localized the mechanical device in position and manually measured the distance from the camera to the TCF upper surface (700 mm in this experiment) and then saved the image in this position as .  (2) We lifted the mechanical device in position   ( mm in this experiment) and then saved the image in this position as .  (3) We did image registration for images and based on SIFT and matched the corresponding pixels in these two images (226 pixels were matched in this experiment). (4) We set the parameters in formula (4). represents lifted distance from to (50 mm in this experiment), represents vertical angle of view (42.6° in this experiment), represents horizontal angle of view (50° in this experiment), represents angle of pitch (21.5° in this experiment), and and represent the coordinates of corresponding pixels in images and . Table 1 showed the horizontal and vertical angles of view of several kinds lens, which had different sizes and focuses. (5) We used formula (4) to calculate the distance from camera to TCF upper surface and compared the calculated results with the actual distance (700 mm in this experiment). The calculation and comparison details were shown in Table 2.

From the comparison shown in Table 2, average deviation is 1.2 mm, and the biggest deviation is 2.2 mm; therefore, we can conclude that the method in Section 2.3 based on monocular vision and image registration can accurately calculate the distance from the camera to TCF upper surface.

3.2. Comparison between Our Method and Single/Double Wire Methods on TCF Thickness Measurement

In this experiment, the results of our method were compared with the traditional methods, which are single-wire measurement method and double-wire measurement method. Although single/double wire measurement methods have several disadvantages, such as easily affected by the operator, dangerous to the operator, and poor repeatability, they are still the most common used and the most accredited methods in continuous casting steelmaking process. Therefore, we took these two methods as the golden standard to verify the correctness and accuracy of our method.

To improve the accuracy of the single/double wire measurement methods and reduce the human interference from the operators as far as possible, two operators were asked to join the experiment and strictly obey the following rules: standing on the secure spot and staying alert; vertically inserting the wires into the molten steel; keeping the hand steady while the wires are in the molten steel; keeping the wires in the molten steel for five seconds; pulling the wires out of the molten steel as quickly as possible while the time is up. One operator measured the TCF thickness using one-wire measurement method, and the other one measured the TCF thickness using two-wire measurement method. While our instrumentation measured the TCF thickness, both operators simultaneously measured the TCF thickness using single/double wire measurement methods. In this way, we can obtain three groups of experimental data at the same time to make the comparison, one from our method, two from single/double wire measurement methods.

The main ingredient of the TCF was shown in Table 3. The operator was asked to add one bag of TCF through each tundish hole every two hours, and the weight of one bag of TCF was about 10 kg.

We did this experiment in two steel plants, respectively, which are Sanming Steel Plant and Nanjing Steel Plant. The error range that can be accepted by the steel plants is  mm. Because the variation of TCF thickness is slow, we measured the TCF thickness every 30 minutes using both our method and the traditional single/double wire measurement methods. The experiments took ten hours in Sanming Steel Plant and nine hours in Nanjing Steel Plant. The measurement results and comparison between our method and the traditional single/double wire measurement methods were shown in Table 4 (Sanming Steel Plant) and Table 5 (Nanjing Steel Plant), and the comparisons were also shown in Figures 17 and 18.

It is shown in Table 4 that in the experiment of Sanming Steel Plant, the biggest deviation of our method from single-wire measurement method is 5.7 mm and the mean deviation of our method from single-wire measurement method is 3.0 mm, and in the experiment of Sanming Steel Plant, the biggest deviation of our method from double-wire measurement method is 6.3 mm and the mean deviation of our method from double-wire measurement method is 2.8 mm.

It is shown in Table 5 that in the experiment of Nanjing Steel Plant, the biggest deviation of our method from single-wire measurement method is 6.4 mm and the mean deviation of our method from single-wire measurement method is 2.1 mm, and in the experiment of Nanjing Steel Plant, the biggest deviation of our method from double-wire measurement method is 7.6 mm and the mean deviation of our method from double-wire measurement method is 3.0 mm.

From Tables 4 and 5, we can conclude that our instrumentation and measurement method can accurately measure the TCF thickness, and our method has higher measurement precision and even can replace single/double wire measurement methods in continuous casting steelmaking process.

It is shown in Figures 17 and 18 that these three groups of measured results (our method, single-wire measurement method, and double-wire measurement method) have similar trend. As time went by, the TCF was melted by the molten steel on and on; therefore, the TCF thickness became thinner and thinner until the operator added one more bag of TCF through the tundish hole. The operator added TCF every two hours (at 2, 4, 6, and 8 hours in Figures 17 and 18); therefore, the TCF thickness became much thicker after the TCF was added.

4. Conclusion

This paper presents a novel measurement method and instrumentation to measure the thickness of TCF in continuous casting steelmaking process. The method is based on computer vision algorithms and the instrumentation is specifically designed and built, which was composed of a measurement bar, a mechanical device, a high-definition industrial camera, a PLC, and a computer. Experiments and results showed that our measurement method and instrumentation can accurately measure the thickness of TCF in continuous casting steelmaking process and had good safety for operators. Furthermore, our measurement method and instrumentation can replace traditional single/double wire measurement methods.

Appendix

The proof of  transformation from image coordinates to world coordinates Suppose that point is any point on the plane ABCD, whose world coordinate is (). And the corresponding point of in the image is , whose image coordinate is (). As shown in Figure 7, point and point have the same vertical coordinate, which is GQ. Therefore, corresponding point of in the image is , and , which shown in Figure 19: Similarly, represents the height of the image:

From formula (A.6), the vertical coordinate of point in the world coordinates system can be obtained from the image coordinate system: GQ, UG, and GL can be obtained by formulas (A.6), (A.8), and (A.9), respectively.

Thus,

From formula (A.11), the horizontal coordinate of point in the world coordinates system can be obtained from the image coordinate system.

Therefore, the transformation from the image coordinates system (, ) to the world coordinates system (, ) is

Acknowledgments

This research was supported by the National Natural Science Foundation of China (no. 61101057) and Shenyang Taihe Metallurgical Measurement and Control Ltd.