Research Article

Simultaneous-Fault Diagnosis of Gas Turbine Generator Systems Using a Pairwise-Coupled Probabilistic Classifier

Table 6

Evaluation of different combinations of techniques using the best model parameters obtained.

ClassifierFeature extractionStrategyExperiment no. Decision thresholdAccuracies for test cases ( )
Single-faultsSimultaneous-faultsOverall faults

PNNNoneOne-versus-all1 = 0.760.83640.71560.7576
WPT + TDSF + KPCAOne-versus-all2 = 0.760.86460.72460.8121

RVMNoneOne-versus-all3 = 0.670.82990.74640.8125
WPT + TDSF + KPCAOne-versus-all4 = 0.670.89600.79640.8536

PCPNNNonePairwise coupling5 = 0.760.89230.73640.7824
WPT + TDSF + KPCAPairwise coupling6 = 0.760.91980.75260.8661

PCRVMNonePairwise coupling7 = 0.670.87950.78430.8497
WPT + TDSF + KPCAPairwise coupling8 = 0.670.93360.83640.9129