Research Article

Simultaneous-Fault Diagnosis of Gas Turbine Generator Systems Using a Pairwise-Coupled Probabilistic Classifier

Table 7

Comparison of SVM, PCPNN, and PCRVM.

ClassifierFeature extractionStrategyExperiment no. Decision thresholdAccuracies for test cases ( )
Single-faultsSimultaneous-faultsOverall faults

SVMWPT + TDSF + KPCAOne-versus-all9Not applicable because of binary outputs of SVM 0.95940.45460.7725

PCPNNWPT + TDSF + KPCAPairwise coupling10 = 0.760.91980.75260.8661

PCRVMWPT + TDSF + KPCAPairwise coupling11 = 0.670.93360.83640.9129