Research Article

Several Treatments on Nonconforming Element Failed in the Strict Patch Test

Table 4

Results of the tip deflection of a cantilever beam subjected to a pure bending .

00.512344.9

Q428.021.014.19.78.37.26.2
Q610078.056.142.541.544.247.4
QM610080.962.754.453.651.246.8
AGQ6-I100100100100100100100
AGQ6M-I10080.855.424.112.99.47.6
AGQ6M-II28.021.214.19.27.35.94.9
AGQ6M10083.866.560.161.460.356.0

Exact100100100100100100100