Research Article
Static Eccentricity Fault Recognition in Three-Phase Line Start Permanent Magnet Synchronous Motor Using Finite Element Method
Table 1
Specification of the three-phase LSPMSM.
| Rated output power (HP) | 1 | Rated voltage (V) | 415 | Rated frequency (Hz) | 50 | Number of poles | 4 | Rated speed (RPM) | 1500 | Air-gap length (mm) | 0.30 | Number of stator slots | 24 | Number of rotor slots | 16 | Effective length of stator core (mm) | 72 | Stator outer diameter (mm) | 120 | Height of stator yoke (mm) | 45 | Height of stator slot (mm) | 13 | Height of rotor slot (mm) | 8 | Number of turns per slot | 139 | Magnet material | N38SH | Remanent flux density of magnets (T) | 1.235 |
|
|