Research Article

Simulation and Experimental Investigation on the AE Tomography to Improve AE Source Location in the Concrete Structure

Table 3

Three hundred and seventy-five AE events source location errors (375AE).

Algorithms Vallen (mm)Simulation (mm)Experiment (mm)

ME 7.599 7.330 7.3500
MR 42.110 39.000 39.300
WAE7.641 7.695 7.7623
SD1.124 1.0523 1.0596