Research Article

A Practical Method of Nonprobabilistic Reliability and Parameter Sensitivity Analysis Based on Space-Filling Design

Table 2

Uncertainty variables of piccolo tube structure.

Variable nameNominal valueConvex model description

Pipeline diameter (m)0.060

Pipeline wall thickness (m)0.002
Hole diameter (m)0.002

Hole side distance (m)0.040
Hole interval length (m)0.04

Hole angle (°) 45

Young’s modulus

Density (kg/m3) 7800

External vibration frequency (Hz)1700