Research Article

Numerical Simulation and Sensitivity Analysis Using RSM on Natural Convective Heat Exchanger Containing Hybrid Nanofluids

Table 6

Levels of input factors and response function.

Run orderCoded valuesReal valuesResponse
A: RaB: HaC: ϕRaHaϕNuav

1000500,500500.0312.854
2−1001,000500.032.9985
3010500,5001000.0312.063
4−1111,0001000.063.5373
50−10500,50000.0313.159
6001500,500500.0613.473
7000500,500500.0312.854
811−11,000,00010008.3363
9−1−1−11,000002.5269
10000500,500500.0312.854
11−1−111,00000.063.5396
12000500,500500.0312.854
131−111,000,00000.0616.695
1400−1500,5005009.2798
15−11−11,00010002.5174
16000500,500500.0312.854
171−1−11,000,0000014.285
181001,000,000500.0315.216
19000500,500500.0312.854
201111,000,0001000.0614.689