Research Article

Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge

Figure 16

Fast discharge with failure of 2 FDUs and earth fault. Maximum voltage at terminal: 8:2, U = 16.35 kV with oscillations t = 5.087 seconds, rise time from 8.06 kV to maximum voltage: 3, 5 milliseconds, maximum terminal to terminal voltage: , kV at t = 5.0819  seconds, rise time from 2.69 kV to maximum kV: 2.4 microseconds.
359210.fig.016