Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge
Figure 16
Fast discharge with failure of 2 FDUs and earth fault. Maximum
voltage at terminal: 8:2, U = 16.35 kV with oscillations t = 5.087 seconds,
rise time from 8.06 kV to maximum voltage: 3, 5 milliseconds, maximum terminal
to terminal voltage: , kV at t = 5.0819 seconds, rise time from 2.69 kV to maximum kV:
2.4 microseconds.