Research Article

Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge

Table 2

Overview of the calculated maximum voltage at ground, radial plate, and conductor insulation for the 1 kHz and 50 kHz model (the elements of network are calculated for 1 kHz and 50 kHz, resp.) of TF coil.

(kHz)Maximum calculated voltage (kV)

Insulation typeFast dischargeFault case 1Fault case 2

Ground13.58.116.4
503.58.116.4
Radial plate10.70.74.8
500.60.74.8
Conductors10.60.84.3
500.50.83.7