Research Article

Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge

Table 3

DC and AC (peak value) test voltages of TF coils for ground, radial plate, and conductor insulation based on the calculated voltages for the two different fault cases.

Test voltages (kV)

InsulationBased on fault case 1Based on fault case 2

Ground1834
Radial plate511
Conductor511