Tab 4
/
Research Article
Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge
Table 4
Overview of the calculated maximum voltages for the 21.5 kHz model of PF coil 4.
Maximum calculated voltage (kV)
Insulation type
Step function
Fault case 1
Fault case 2
Ground
4.8
3.3
2.9
Radial plate
0.9
0.9
1.0
Conductors
1.0
0.9
1.2