Research Article

Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge

Table 4

Overview of the calculated maximum voltages for the 21.5 kHz model of PF coil 4.

Maximum calculated voltage (kV)

Insulation typeStep functionFault case 1Fault case 2

Ground4.83.32.9
Radial plate0.90.91.0
Conductors1.00.91.2