Research Article
A New Approach to the Identification of Distillation Column Based on Hammerstein Model
Table 1
Nominal operating conditions and the column parameters.
| Number of trays | 15 | Feed tray number | 8 | Column diameter | 10.8 cm | Weir height | 2 cm | Weir length | 8.3 cm | Feed composition | 0.308 | Feed flow rate | 1 kmol/h | Distillate composition | 0.98 | Distillate flow rate | 0.31 kmol/h | Bottoms flow rate | 0.69 kmol/h | Reflux flow rate | 1.09 kmol/h | Reflux drum holdup | 0.015 m3 | Reboiler holdup | 0.007 m3 | Mol. weight of methanol | 32 kg/kmol | Mol. weight of water | 18 kg/kmol |
|
|