Research Article

A New Approach to the Identification of Distillation Column Based on Hammerstein Model

Table 1

Nominal operating conditions and the column parameters.

Number of trays15
Feed tray number8
Column diameter10.8 cm
Weir height2 cm
Weir length8.3 cm
Feed composition0.308
Feed flow rate1 kmol/h
Distillate composition0.98
Distillate flow rate0.31 kmol/h
Bottoms flow rate0.69 kmol/h
Reflux flow rate1.09 kmol/h
Reflux drum holdup0.015 m3
Reboiler holdup0.007 m3
Mol. weight of methanol32 kg/kmol
Mol. weight of water18 kg/kmol