Research Article

A Segmental Approach with SWT Technique for Denoising the EOG Signal

Table 2

RMSE values obtained between reference EOG signal and denoised EOG signals by increasing segments approach using RLS adaptive filtering technique.

S. numberSegment of the signal (samples) EOG5 dB
SNR = 39.04 dB
EOG10 dB
SNR = 33.92 dB
EOG15 dB
SNR = 29.02 dB
EOG20 dB
SNR = 24.12 dB
EOG25 dB
SNR = 19.01 dB
RMSE (µV)RMSE (µV)RMSE (µV)RMSE (µV)RMSE (µV)

11:51236.1235.9236.4236.4936.20
21:102425.5425.4025.7625.8425.71
31:153620.8520.7521.0521.1321.12
41:204818.0617.9718.2418.3318.38
51:256022.0021.9322.1622.1822.15
61:307222.0920.0320.2320.2620.28
71:358422.0521.9922.1222.1922.11
81:409620.6320.5720.6920.7720.72
91:460822.3022.3222.4022.5722.51
101:512021.6321.6521.7421.8821.86
111:563223.8023.8123.9424.1123.98
121:614426.6926.6926.8327.0426.87
131:665628.1328.1528.2228.5028.31
141:716830.0830.1330.2130.4430.32
151:768029.0629.1029.1929.4129.31
161:819228.8728.9128.9829.1629.10

Maximum value36.1235.9236.4236.4936.20

Minimum value18.0617.9718.2418.3318.38

Mean (µV)24.8724.7124.8925.0224.93

Standard deviation (µV)4.654.764.784.814.74