Research Article

A Segmental Approach with SWT Technique for Denoising the EOG Signal

Table 4

RMSE values obtained between reference EOG signal and denoised EOG signals by different equal segments approach using RLS adaptive filtering technique.

S. numberSegment of the signal (samples) EOG5 dB
SNR = 39.04 dB
EOG10 dB
SNR = 33.92 dB
EOG15 dB
SNR = 29.02 dB
EOG20 dB
SNR = 24.12 dB
EOG25 dB
SNR = 19.01 dB
RMSE (µV)RMSE (µV)RMSE (µV)RMSE (µV)RMSE (µV)

2513:102434.4734.4834.3934.6034.45
31025:153634.4534.3934.3534.6034.65
41537:204834.4234.4334.4934.3834.60
52049:256047.9447.9248.0748.1047.87
62561:307213.9713.9914.0714.0014.45
73073:358424.2733.2933.0933.3733.01
83585:409638.0338.0338.0837.9738.31
94097:460850.1750.4350.2835.8850.60
104609:512018.0618.0418.2418.0118.45
115121:563239.4039.4139.7540.1439.33
125633:614448.2148.0948.3948.8048.37
136145:665641.6941.8941.4341.8541.92
146657:716848.8619.0849.2649.5249.54
157169:768022.4122.3322.4022.5923.02
167681:819234.1134.1234.1033.4933.95

Maximum value50.1750.4350.2849.5250.60

Minimum value13.9713.9914.0714.0014.45

Mean (µV)35.3634.0036.0235.1536.17