Clinical Study

Validity and Reproducibility of the Measurements Obtained Using the Flexicurve Instrument to Evaluate the Angles of Thoracic and Lumbar Curvatures of the Spine in the Sagittal Plane

Table 1

Intraclass Correlation Coefficient (ICC) between the evaluations of the thoracic and lumbar curvatures measured with the flexicurve performed by three different evaluators (Eva1, Eva2, and Eva3) and between the first and second evaluation days performed by the same evaluator (day1, day2).

95% Confidence interval
ICCInferior limitSuperior limitP

Thoracic (Eva1, Eva2, and Eva3)0.9420.8650.979
Lumbar (Eva1, Eva2, and Eva3)0.8310.6040.938
Eva1 (day1) × Eva1 (day2): Thoracic0.8290.5650.939
Eva1 (day1) × Eva1 (day2): Lumbar0.7830.4680.922