Science and Technology of Nuclear Installations
Volume 2008 (2008), Article ID 405072, 5 pages
http://dx.doi.org/10.1155/2008/405072
Research Article

Theoretical and Numerical Study of Heat Transfer Deterioration in High Performance Light Water Reactor

Department of Reactor Technology, Albanova University Center, Royal Institute of Technology (KTH), 106 91 Stockholm, Sweden

Received 10 March 2008; Accepted 7 August 2008

Academic Editor: Ivo Kljenak

Copyright © 2008 David Palko and Henryk Anglart. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

A numerical investigation of the heat transfer deterioration (HTD) phenomena is performed using the low-Re k- turbulence model. Steady-state Reynolds-averaged Navier-Stokes equations are solved together with equations for the transport of enthalpy and turbulence. Equations are solved for the supercritical water flow at different pressures, using water properties from the standard IAPWS (International Association for the Properties of Water and Steam) tables. All cases are extensively validated against experimental data. The influence of buoyancy on the HTD is demonstrated for different mass flow rates in the heated pipes. Numerical results prove that the RANS low-Re turbulence modeling approach is fully capable of simulating the heat transfer in pipes with the water flow at supercritical pressures. A study of buoyancy influence shows that for the low-mass flow rates of coolant, the influence of buoyancy forces on the heat transfer in heated pipes is significant. For the high flow rates, buoyancy influence could be neglected and there are clearly other mechanisms causing the decrease in heat transfer at high coolant flow rates.

1. Introduction

High performance light water reactor (HPLWR) is one of the six Gen-IV reactor concepts, based on the existing boiling and pressurized water reactors. Water at high pressures (), used as a cooling medium, allows significant increase of the system thermal efficiency. As the reactor is designed to operate at supercritical pressure, there is no phase change between liquid and vapor phase and, therefore, the boiling crisis is inherently avoided. However, close to the pseudocritical point, where the thermophysical properties vary significantly, the heat transfer shows unusual behavior. Enhanced, normal, or deteriorated heat transfer regime may exist depending on the flow parameters and the applied heat flux.

In the deteriorated region, the heat transfer coefficient decreases causing the increase in wall temperature. As shown by several experiments (Shitsman [1], Kirillov et al. [2], or Ornatskij et al. [3]), the increase in wall temperature is not as rapid as in case of boiling crisis in classical light water reactors. Due to the relatively mild increase in wall temperature, the onset of HTD is not well defined. Many different definitions are used in the literature. For example, Koshizuka et al. [4] defined the onset of HTD as the following ratio: where is the heat transfer coefficient calculated numerically by Jones-Launder’s k- model using constant properties at bulk liquid temperature. Heat transfer is considered to be deteriorated when .

The modified Koshizuka’s criterion for the onset of the HTD is frequently used. Here, is calculated using the Dittus-Boelter [5] correlation: with thermophysical properties evaluated at the bulk liquid temperature. Differences in the definition of the onset of the HTD could lead to the relevant differences in its prediction. However, for the present study the exact definition is not relevant, as all the simulations are performed in the highly deteriorated region.

2. Numerical Modeling Issues

The effect of buoyancy and its influence on the heat transfer is simulated numerically, using the Ansys-CFX 11.0 computational code, for steady-state flow within heated pipes. Computational domain consists of 30 degree slide of a pipe and the mesh is a standard hexahedral with approximately 2500000 grid points with refinement close to the wall, such as the nondimensional distance from the wall is below 1. All simulations which include heat transfer require proper resolution of the boundary layer. The standard k- turbulence model offers very robust and reliable modeling of turbulence for the bulk flow. However, for the near wall region (), the flow is approximated by wall functions. This means that the whole viscous sublayer and part of the buffer layer is not resolved numerically with the k- model.

The standard k- turbulence model, as developed by Wilcox [6], allows resolving the viscous sublayer. However, this model is known to be sensitive to the free stream conditions. Strong variations of final results could occur depending on the value of the turbulent frequency specified at the inlet.

The shear stress transport (SST) model, as developed by Menter [7], combines the robustness of the k- model for the bulk flow and the low-Re treatment of the boundary layer using the modified Wilcox k- model.

As the validation of different cases against the experimental data proves, the low-Re SST model is fully capable of modeling the heat transfer to supercritical water (including the deteriorated region) and the calculated results are in a very good agreement with the experimental data. This is demonstrated in Figure 1, where the comparison of SST and k- turbulence models is shown for the experiment by Ornatskij et al. [3] (described later). The heat transfer coefficient is plotted against the bulk fluid temperature.

405072.fig.001
Figure 1: Comparison of SST turbulence model, k- model and experiment by Ornatskij et al. [3]. Flow conditions: , , , , vertical upward flow in a pipe.

The k- model fails to calculate the heat transfer to supercritical fluid in deteriorated region. The SST model predicts the heat transfer coefficient in a very good agreement with the experimental results. The main reason for the substantial difference in results for these two turbulence models is the near wall treatment. SST model allows resolving the boundary layer numerically. Standard k- turbulence model approximates the boundary layer by wall functions (for coarse grid, ), which are not suitable for the flows where the thermophysical properties changes rapidly close to the wall. For the very fine grids (), the nonlinear damping functions, required for the k- model, cause the loss of accuracy and so the final results differ substantially from the experimental values.

Sensitivity analysis for the grid size is also made for the SST model. In order to resolve the boundary layer, the nondimensional distance of the first computational cell from the wall () should be kept below 1. Figure 2 proves that if this condition is fulfilled, the results are insensitive to the grid size. This behavior results from the implementation of the wall treatment by SST turbulence model in Ansys CFX-11.0 computational software. Here, if the nondimensional distance of the first computational cell is bigger than 1, the near wall region is approximated by wall functions, which leads to the similar behavior of results as in the case of k- model. If the distance is smaller than , boundary layer is resolved numerically leading to the correct solution.

405072.fig.002
Figure 2: Sensitivity analysis on the grid size for the SST turbulence model, comparison with the experiment by Ornatskij et al. [3]. Flow conditions: , , , , vertical upward flow in a pipe.

3. Influence of Buoyancy on Heat Transfer

Once the correct numerical results are obtained, the influence of buoyancy on heat transfer could be studied by the comparison of the solution obtained with and without the buoyancy terms in the governing equations. The expected influence of buoyancy can be examined by the ratio of Grashof and Reynolds numbers where is the gravitational constant, is the thermal expansion coefficient, is the characteristic length, is the temperature change, and is the velocity of coolant. For the normal operating conditions in the pressurized water reactors (PWRs), this ratio is small due to the very high flow velocities, relatively small change in temperature and the low value of the thermal expansion coefficient. Therefore, the buoyancy influence on heat transfer could be neglected in conditions typical for PWRs.

However, for the HPLWR conditions, even though, the flow velocity is relatively high, there is a strong change in thermophysical properties, namely, density and thermal expansion coefficient, thus the ratio of Grashof and Reynolds numbers may be relevant. It should be pointed out that the buoyancy is not the only phenomenon causing the HTD. Its influence strongly depends on the flow conditions. Several resources show that other effects, such as the streamwise acceleration (McEligot and Jackson [8]) or the direct change of the thermophysical properties (Koshizuka et al. [4]), could cause the heat transfer to deteriorate.

In the vertical pipes with upward flow, the buoyancy accelerates the flow close to the wall, where there is the highest density difference. The increase of velocity causes the decrease of the velocity gradient and thus the decrease of the turbulent kinetic energy. Loss of the turbulence close to the wall then decreases the heat transfer coefficient. In order to examine this effect, Mikielewicz et al. [9] proposed the following nondimensional number: which applies for arbitrary heated surfaces in a vertical duct ( is a distance near the edge of the viscous layer, Jackson [10] proposed 26). is defined as: Here, is the gravitational constant, is the kinematic viscosity, is density, subscripts and correspond to the wall and bulk conditions, respectively, is the Nusselt number, is the Reynolds number, Pr is the Prandtl number and is the friction factor. All of these nondimensional quantities are evaluated at bulk conditions.

According to Mikielewicz et. al. [9], corresponds to the onset of significant buoyancy effects. When applying the Dittus-Boelter correlation (2) and Blasius correlation for the friction factor, (4) can be written as follows (neglecting the differences between wall and bulk densities, resp., viscosities): where . Then the onset of significant buoyancy influence is expressed as

4. Numerical Results and Discussion

Two different experiments are numerically simulated with Ansys CFX-11.0 computational software, using the SST turbulence model in order to examine the influence of buoyancy on the heat transfer. Experiments by Shitsman [1] and Ornatskij et al. [3] were chosen due to the following reasons.

Both experiments measure the heat transfer in the highly deteriorated region. The experiment by Ornatskij et al. [3] is performed for very high-coolant flow rate, where the buoyancy force should have no effect on the heat transfer according to (7). On the other hand, experimental data by Shitsman [1] are in the region of high-buoyancy influence.

4.1. Heat transfer at Low-Coolant Flow Rates

Flow simulation at low-coolant flow rate is demonstrated in the experiment by Shitsman [1]. This experiment is performed with supercritical water at in a pipe with inner diameter . The pipe is uniformly heated with a heat flux of and the coolant flow rate is . For these flow parameters, Mikielewicz condition for the influence of buoyancy is fulfilled.

These flow conditions are modeled on a 30 degrees slice of pipe geometry with approximately 2500000 computational hexahedral cells. Boundary conditions consist of specification of constant pressure at the outlet, mass flow rate, respectively, velocity at the inlet and no slip + constant heat flux boundary conditions at the walls. Symmetry b.c is applied at the symmetry walls.

Comparison of the numerical results with the experimental data is shown in Figure 3, where the wall temperature is plotted against the bulk enthalpy. There is a very good agreement between CFX-11.0 results and experimental data. The solver is capable of capturing also the deteriorated region represented by the two peaks in the wall temperature.

405072.fig.003
Figure 3: Comparison of the numerical results with the experiment by Shitsman [1] and the correlation by Dittus-Boelter. Flow conditions: , , , , vertical upward flow in a pipe.

Solving the same equations on an identical numerical grid without the buoyancy terms in the NS equations leads to substantial underprediction of the wall temperature. This means that the buoyancy terms in Navier-Stokes equations are responsible for the increase in the wall temperature and hence the heat transfer deterioration is caused by the buoyancy force, as was predicted by (7). A possible explanation of this phenomenon is that the buoyancy accelerates the flow close to the wall leading to the more flat velocity profile, decrease in the velocity gradient and decrease of turbulence. Decrease in turbulence then leads to the decrease of the heat transfer coefficient, and thus to the increase in wall temperature.

The Dittus-Boelter correlation (2) prediction of the wall temperature is plotted to visualize how the heat transfer regime differs from the normal regime.

4.2. Heat Transfer at High Coolant Flow Rates

For the high flow rates, when the condition is not fulfilled, the buoyancy could be neglected according to Mikielewicz et al. [9]. Such a flow is demonstrated by the experiment of Ornatskij et al. [3]. Here, the flow parameters of supercritical water at are measured in a pipe with inner diameter . The pipe is uniformly heated with heat flux of and the coolant flow rate is .

Even though the buoyancy should not be relevant, heat transfer is still deteriorated (as measured by Ornatskij et al. [3]) according to the definition: where is an ideal heat transfer coefficient calculated with the Dittus-Boelter correlation (2) with the properties evaluated at the bulk temperature.

Numerical results and the comparison with the experiment and Dittus-Boelter correlation are shown in Figure 4. The influence of buoyancy is small and there are clearly other mechanisms which cause the decrease in heat transfer. According to Koshizuka et al. [4], change in the thermophysical properties, such as viscosity and thermal conductivity, may lead to the decrease in heat transfer coefficient. The influence of these phenomena could be demonstrated in the same way as the influence of buoyancy, if numerical simulations with constant and variable properties are compared.

405072.fig.004
Figure 4: Comparison of the numerical results with the experiment by Ornatskij [3] and the correlation by Dittus-Boelter. Flow conditions: , , , , vertical upward flow in a pipe.

5. Conclusions

The present work demonstrates the ability of the low-Re RANS turbulence treatment to model the heat transfer under supercritical pressure. Proper grid resolution of the boundary layer and the accuracy in thermophysical properties show very high influence on final results.

Buoyancy influence on the heat transfer deterioration was demonstrated. The results proved that under some conditions, buoyancy is the phenomenon that governs the heat transfer deterioration, mainly for relatively low coolant flow rates and high heat fluxes. However, for high coolant flow rates, there exist clearly other mechanisms which have to be identified and examined in order to be able to successfully predict the onset of HTD.

Acknowledgment

Authors would like to acknowledge the financial support from the European Commission.

References

  1. M. E. Shitsman, “Impairment of the heat transmission at supercritical pressures,” High Temperatures, vol. 1, no. 2, pp. 237–244, 1963.
  2. P. Kirillov, R. Pomet'ko, A. Smirnov, et al., “Experimental study on heat transfer to supercritical water flowing in 1-and 4-m-long vertical tubes,” in Proceedings of the International Conference on Nuclear Energy Systems for Future Generation and Global Sustainability (GLOBAL '05), pp. 1–8, Tsukuba, Japan, October 2005, paper 518.
  3. A. P. Ornatskij, L. F. Glushchenko, and S. I. Kalachev, “Heat transfer with rising and falling flows of water in tubes of small diameter at supercritical pressures,” Thermal Engineering, vol. 18, no. 5, pp. 137–141, 1971.
  4. S. Koshizuka, N. Takano, and Y. Oka, “Numerical analysis of deterioration phenomena in heat transfer to supercritical water,” International Journal of Heat and Mass Transfer, vol. 38, no. 16, pp. 3077–3084, 1995. View at Publisher · View at Google Scholar
  5. F. W. Dittus and L. M. K. Boelter, Heat Transfer in Automobile Radiators of the Tubular Type, vol. 2 of University of California Publications in Engineering, University of California Press, Berkeley, Calif, USA, 1930.
  6. D. C. Wilcox, “Multiscale model for turbulent flows,” in Proceedings of the 24th AIAA Aerospace Sciences Meeting, pp. 1311–1320, American Institute of Aeronautics and Astronautics, Reno, Nev, USA, January 1986.
  7. F. R. Menter, “Multiscale model for turbulent flows,” in Proceedings of the 24th AIAA Fluid Dynamics Conference, pp. 1311–1320, American Institute of Aeronautics and Astronautics, Orlando, Fla, USA, July 1993.
  8. D. M. McEligot and J. D. Jackson, ““Deterioration” criteria for convective heat transfer in gas flow through non-circular ducts,” Nuclear Engineering and Design, vol. 232, no. 3, pp. 327–333, 2004. View at Publisher · View at Google Scholar
  9. D. P. Mikielewicz, A. M. Shehata, J. D. Jackson, and D. M. McEligot, “Temperature, velocity and mean turbulence structure in strongly heated internal gas flows. Comparison of numerical predictions with data,” International Journal of Heat and Mass Transfer, vol. 45, no. 21, pp. 4333–4352, 2002. View at Publisher · View at Google Scholar
  10. J. D. Jackson, “Consideration of the heat transfer properties of supercritical pressure water in connection with the cooling of advanced nuclear reactors,” in Proceedings of the 13th Pacific Basin Nuclear Conference (PBNC '02), pp. 21–25, Shenzen City, China, October 2002.