Table 4:
Values of the performance indices (RMSE, MAE, MRE) calculated over different test sets for the buffered MLP, FIR-MLP, and IIR-LRNN trained to estimate the reactor neutron flux dynamics.
Buffered MLP
Errors
Forcing function
Number of sequences
RMSE
MAE
MRE
Step
80
0.0805
0.0523
0.0051
Ramp
80
0.0751
0.0503
0.0065
Sine
80
0.0763
0.0513
−
0.0041
Random
80
0.0792
0.0520
0.0047
FIR-MLP
Errors
Forcing function
Number of sequences
RMSE
MAE
MRE
Step
80
0.0753
0.0487
0.0024
Ramp
80
0.0698
0.0435
0.0050
Sine
80
0.0705
0.0450
−
0.0035
Random
80
0.0748
0.0482
0.0038
IIR-LRNN
Errors
Forcing function
Number of sequences
RMSE
MAE
MRE
Validation Step
80
0.0098
0.0060
−
0.0003
Ramp
80
0.0049
0.0039
0.0037
Sine
80
0.0058
0.0051
−
0.0011
Random
80
0.0063
0.0054
0.0021