Project Report

The SPES3 Experimental Facility Design for the IRIS Reactor Simulation

Table 1

IRIS and SPES3 characteristic comparison.

System/ComponentIRISSPES3

Primary side integral RPVyesyes apart the pump
Pumps81
Core power (MW)10006.5
EBT22
Steam Generators83
Secondary loops43
SG tubes~70014, 14, 28
SG height (m)8.28.2
SG tube average length3232
Containment systemyesyes
EHRS43
RWST22
Dry Well11
PSS22
LGMS22
QT11
ADS trains32