Review Article

Experiments and Modelling Techniques for Heat and Mass Transfer in Light Water Reactors

Table 1

Boundary conditions for the dry and wet EFFE tests addressed by FLUENT calculations [15].

Air flow
Test no.Average plate temperature (°C)Inlet temperature (°C)Relative humidity (%)Mean inlet velocity (m/s)

DryDTI57.820.847.60.87
DT256.921.247.54.25
DT357.524.043.37.47

WetWTI60.323.530.90.78
WT260.823.634.64.07
WT360.525.038.27.24