Research Article
Application of REPAS Methodology to Assess the Reliability of Passive Safety Systems
Table 3
Design parameters case b.
| Design parameter ID | Description | UNIT | Nominal value | Range | Discrete initial value |
| P1 | RPV Pressure | MPa | 7 | 0.2–9 | 0.2 1 3 7 10 | 0.05 0.1 0.15 0.5 0.2 | L1 | RPV collapse level | M | 8.7 | 5–12 | 5 7 8.7 10 12 | 0.05 0.1 0.5 0.2 0.15 | L3 | POOL level | M | 4.3 | 2–5 | 2 4.3 5 | 0.1 0.8 0.1 | Tp (0) | POOL initial temperature | K | 303 | 280–368 | 280 303 368 | 0.1 0.8 0.1 | — | System geometry layout | — | — | Not assigned | — | 1.0 |
|
|