Research Article

Investigation of a Coolant Mixing Phenomena within the Reactor Pressure Vessel of a VVER-1000 Reactor with Different Simulation Tools

Table 2

Main parameters of the four loops before the test.

ParameterInitial stateAccuracy

Thermal power, MW281±60
Pressure above core, MPa15.593±0.300
Pressure drop over RPV, MPa0.418±0.043
Coolant temperature at core inlet #1, K541.75±1.50
Coolant temperature at core inlet #2, K541.85±1.50
Coolant temperature at core inlet #3, K541.75±1.50
Coolant temperature at core inlet #4, K541.75±1.50
Coolant temperature at core outlet #1, K545.00±2.00
Coolant temperature at core outlet #2, K545.00±2.00
Coolant temperature at core outlet #3, K544.90±2.00
Coolant temperature at core outlet #4, K545.00±2.00
Mass flow rate of loop #1, kg/s4737±110
Mass flow rate of loop #2, kg/s4718±110
Mass flow rate of loop #3, kg/s4682±110
Mass flow rate of loop #4, kg/s4834±110