Research Article
Investigation of a Coolant Mixing Phenomena within the Reactor Pressure Vessel of a VVER-1000 Reactor with Different Simulation Tools
Table 5
Main parameters of the NPP at the end of the test (1800 seconds).
| Parameter | Final state | Accuracy |
| Thermal power, MW | 286 | | Pressure above core, MPa | 15.593 | | Pressure drop over RPV, MPa | 0.417 | | Coolant temperature at core inlet #1, K | 555.35 | | Coolant temperature at core inlet #2, K | 543.05 | | Coolant temperature at core inlet #3, K | 542.15 | | Coolant temperature at core inlet #4, K | 542.35 | | Coolant temperature at core outlet #1, K | 554.85 | | Coolant temperature at core outlet #2, K | 548.55 | | Coolant temperature at core outlet #3, K | 545.75 | | Coolant temperature at core outlet #4, K | 546.45 | | Mass flow rate of loop #1, kg/s | 4566 | | Mass flow rate of loop #2, kg/s | 4676 | | Mass flow rate of loop #3, kg/s | 4669 | | Mass flow rate of loop #4, kg/s | 4816 | |
|
|