Research Article

Investigation of a Coolant Mixing Phenomena within the Reactor Pressure Vessel of a VVER-1000 Reactor with Different Simulation Tools

Table 4

Comparison of TRACE predictions with plant data for the final state.

ParameterFinal stateAccuracyTRACEDeviation

Thermal power, MW286±602860.000
Pressure above core, MPa15.593±0.30015.5910.002
Pressure drop over RPV, MPa0.417±0.0430.4040.013
Coolant temperature at core inlet #1, K555.35±1.50555.39-0.04
Coolant temperature at core inlet #2, K543.05±1.50543.08-0.03
Coolant temperature at core inlet #3, K542.15±1.50542.18-0.03
Coolant temperature at core inlet #4, K542.35±1.50542.38-0.03
Coolant temperature at core outlet #1, K554.85±2.00555.14-0.29
Coolant temperature at core outlet #2, K548.55±2.00548.66-0.11
Coolant temperature at core outlet #3, K545.75±2.00545.440.31
Coolant temperature at core outlet #4, K546.45±2.00545.690.76
Mass flow rate of loop #1, kg/s4566±1104657-91
Mass flow rate of loop #2, kg/s4676±1104693-17
Mass flow rate of loop #3, kg/s4669±1104724-55
Mass flow rate of loop #4, kg/s4816±110472492