RELAP5/MOD3.3 Best Estimate Analyses for Human Reliability Analysis

Table 3

Sequence of main events for 2.54 cm LOCA calculations.

Time (s)
Analyzed casesABCDEF

Break occurrence0.00.00.00.00.00.0
Rx trip signal generation108.6112.5112.5112.5112.5112.5
Turbine trip108.7112.5112.5112.5112.5112.5
SI signal generation118.9122.9122.9122.9122.9122.9
MFW isolation118.9122.9122.9122.9122.9122.9
steamline isolation1568.82338.23437.55124.06124.97320.8
Accumulator no. 1 injection2202.12541.13617.05274.26497.77631.4
Accumulator no. 2 injection2202.02541.13617.05274.06497.57631.3
Accumulator no. 1 isolation3299.05511.55706.16157.17325.48575.3
Accumulator no. 2 isolation3298.05510.45705.16157.27325.38575.0