Research Article

RELAP5/MOD3.3 Best Estimate Analyses for Human Reliability Analysis

Table 5

Sequence of main events for LOCA calculations without SI signal.

Time (second)
Analyzed break sizes1.91 cm2.54 cm5.08 cm7.62 cm10.16 cm15.24 cm

Break occurrence0.00.00.00.00.00.0
Rx trip signal generation274.2112.521.53.32.92.6
Turbine trip274.2112.521.53.32.92.7
conditions for automatic SI signal generation282.4122.929.613.48.96.3
Accumulator no. 1 injectionN.A.N.A.1802.2712.2391.8189.0
Accumulator no.2 injectionN.A.N.A.1802.0712.0391.7188.9
Accumulator no. 1 isolationN.A.N.A.8612.34146.31720.2625.9
Accumulator no.2 isolationN.A.N.A.8612.34146.91752.9625.7