Research Article
Assessment of an Isolation Condenser of an Integral Reactor in View of Uncertainties in Engineering Parameters
Table 1
Relevant selected parameters and their distributions.
| ID | Description | Distribution |
| 1-OP | Operational power | Normal | 2-SD1 | SCRAM delay | Log-norm | 3-SD2 | Safety rods total drop time | Log-norm | 4-DF | Decay power factor | Log-norm | 5-P1 | Nominal Pressure | Normal | 6-SP | SCRAM: pressure set-point | Normal | 7-P2 | IC: pressure set point | Normal | 8-L | RPV dome water level | Normal | 9-M | PCS mass flow rate | Normal | 10-T2 | IC valves opening time | Normal | 11-PT | PHRHS pool temperature | Log-norm | 12 -TT | IC tube thickness | Normal | 13-C2 | Heat losses in IC vapor line | Normal | 14-W1 | IC tube thickness: fouling | Log-norm | 15-HL | RPV dome heat losses (in steam zone) | Normal | 16-F | IC friction | Normal |
|
|