Research Article
A Procedure to Address the Fuel Rod Failures during LB-LOCA Transient in Atucha-2 NPP
Table 3
Main outcomes from the analysis: zones 1, 4, and 5.
| Parameter | Average Zone 1 | Average Zone 4 | Average Zone 5 | Max |
| T cladding [°C] | 579.7 | 841.0 | 823.5 | 959.5 | T Fuel cl [°C] | 760.7 | 1595.8 | 1625.4 | 1860.7 | Enthalpy [cal/g] | 45.0 | 83.7 | 83.7 | 99.1 | Gap P [MPa] | 5.7 | 7.3 | 7.5 | 7.74 | FGR [%] | 1.9 | 0.2 | 0.2 | 3.17 | Gap width [μm] | 58.8 | 47.2* | 50.6 | 60.0 | Cladding outer radius [mm] | 6.46 | 6.48 | 6.47 | 7.6 | ECR [%] | 0.45 | 0.42 | 0.40 | 0.58 | Ox Thick. [μm] | 3.25 | 3.06 | 2.92 | 4.24 |
|
|
*Rod no. 267_BL21 excluded from the calculation of the average and maximum.
|