Research Article

Remarks on Consistent Development of Plant Nodalizations: An Example of Application to the ROSA Integral Test Facility

Table 1

Percentual error between the calculated steady state and the experimental values.

Percentual error (%)

Core power 0.0
DC to UH bypass flow 17.0
Hot leg to DC bypass flow 17.0
Primary pressure 0.3
Hot leg fluid temperature 0.3
Cold leg fluid temperature 0.2
Mass flow rate 0.0
Pressurizer level 2.0
Main steam pressure 0.0
Secondary side liquid level 0.5
Steam flow rate 1.9
Main feedwater flow rate 1.5