Research Article
Remarks on Consistent Development of Plant Nodalizations: An Example of Application to the ROSA Integral Test Facility
Table 1
Percentual error between the calculated steady state and the experimental values.
| | Percentual error (%) |
| Core power | 0.0 | DC to UH bypass flow | 17.0 | Hot leg to DC bypass flow | 17.0 | Primary pressure | 0.3 | Hot leg fluid temperature | 0.3 | Cold leg fluid temperature | 0.2 | Mass flow rate | 0.0 | Pressurizer level | 2.0 | Main steam pressure | 0.0 | Secondary side liquid level | 0.5 | Steam flow rate | 1.9 | Main feedwater flow rate | 1.5 |
|
|