About this Journal Submit a Manuscript Table of Contents
Science and Technology of Nuclear Installations
Volume 2012 (2012), Article ID 275693, 20 pages
http://dx.doi.org/10.1155/2012/275693
Research Article

Experimental Studies for the VVER-440/213 Bubble Condenser System for Kola NPP at the Integral Test Facility BC V-213

1Thermo-Hydraulics Division, Electrogorsk Research and Engineering Center for Safety of Nuclear Power Plants, Saint Constantine Street 6, Electrogorsk, Moscow 142530, Russia
2Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) mbH, Kurfürstendamm 200, 10719 Berlin, Germany

Received 3 May 2011; Accepted 19 August 2011

Academic Editor: Alessandro Del Nevo

Copyright © 2012 Vladimir N. Blinkov et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. A. M. Bukrinsky, Y. V. Rzheznikov, Y. V. Shvyryaev, et al., “Accident Localization System under LB LOCA conditions at NPP with VVER-440,” Thermal Engineering, no. 4, pp. 47–49, 1978.
  2. “Bubble condenser experimental qualification (PH 2.13/95),” Final Thermal-Hydraulic Test Report BC-D-ER-SI-0028, Rev. 0. Task 2: Deliverable 2.4, 1999.
  3. “Experimental Studies on: A. Bubble Condenser Test Facility (R2.01/99). B. TKR Test Facility (R2.02/99) at EREC-Electrogorsk, Re-mobilization of the BC V-213 test facility and result of comparative experiment,” Tech. Rep. BC-TR-01E, 2003.
  4. “Experimental studies on: A. Bubble condenser test facility (r2.01/99). b. TKR test facility (r2.02/99) at EREC-Electrogorsk. modification of the test facility for the Kola NPP tests,” Tech. Rep. BC-TR-02E, 2003.
  5. “Bubble condenser experimental qualification (PH 2.13/95),” Test Matrix Development BC-D-ER-SI-0006, Rev. 5. Deliverable 2.2, Part 2 of 6, 1999.
  6. ATHLET Mod 1.2 Cycle D, “User’s Manual, GRS-P-1/1,” September 2001.
  7. COCOSYS V1.2, “User Manual, GRS-P-3/1,” July 2000.
  8. H. Wolff, et al., “Pre-and post-test calculations of the EREC experiment SLB G02 Project INT 9142, Task 3.1,” Tech. Rep. GRS-V-INT 9142-6/2003, Berlin, Germany, 2003.
  9. “Input Data Base for WWER 440/W213 Systems,” Tech. Rep. RF13-TR02, 2000.
  10. “Experimental,” Tech. Rep. BC-TR-03E, 2003.
  11. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk. Test plan and pre-test calculations,” Tech. Rep. BC-TR-04E, 2003.
  12. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk. Results of LB LOCA test 5,” type BC-TR-05E, 2003.
  13. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk. Results of LB LOCA test 1,” Tech. Rep. BC-TR-06E, 2003.
  14. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk. Results of MSLB test 7,” type BC-TR-07E, 2003.
  15. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk. Results of MSLB test 9,” Tech. Rep. BC-TR-08E, 2003.
  16. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk. Results of SB LOCA test 12,” Tech. Rep. BC-TR-09E, 2003.
  17. I. E. Idel'chik, Handbook on Hydraulic Resistances, Moscow, Russia, 1992.
  18. “Answers to remaining questions on Bubbler Condenser,” Activity Report of the OECD NEA Bubbler-Condenser Steering Group NEA/CSNI/R, 2003.
  19. “Experimental studies on: a. Bubble condenser test facility (R2.01/99). B. TKR test facility (R2.02/99) at EREC-Electrogorsk,” Tech. Rep., 2005.