| Parameter | Value |
|
| Upper plenum pressure, (MPa) | 12.24 |
| Core outlet temperature of coolant, (°C) | 297.2 |
| Core inlet temperature of coolant, (°C) | 267.1 |
| Loop flow rate, (kg/s) | 1463 |
| Main coolant pump pressure difference, (MPa) | 0.47 |
| Pressurizer temperature, (°C) | 325.7 |
| Pressurizer level, (m) | 5.97 |
| Core power, (MW) | 1375 |
| Steam generator pressure, (MPa) | 4.66 |
| Live steam temperature, (°C) | 259.5 |
| Feed water temperature, (°C) | 222.8 |
| Live steam and feed water flow rate, (kg/s) | 128 |
| Water level in steam generator, (m) | 1.831 |
| Power of steam generators, (MW) | 1375 |
| Initial pressure in hydroaccumulators, (MPa) | 5.9 |
| Initial water level in hydroaccumulators, (m) | 5.6 |
| Water temperature in hydroaccumulators, (°C) | 55 |
| Pressure in low pressure system, (MPa) | 0.695 |
|