Research Article

Analysis of the NUPEC PSBT Tests with FLICA-OVAP

Table 2

Range of parameters for the Shah model covered by the NUPEC tests.

[m] / (max/min) (max min) (max min)

Series 00.009711376.674944.4 1408.3−0.062 −0.960.49 −0.20
Series 20.009711376.674769.4 316.7−0.053 −0.971.00 −0.06
Series 30.009989366.214702.8 1361.1−0.045 −0.870.58 −0.05
Series 40.009711376.674725.0 566.7−0.058 −0.981.00 0.06
Series 130.009711376.673861.1 1361.1−0.057 −0.500.50 0.20
Series 80.008867412.554816.7 575.0−0.058 −0.971.00 0.11