Research Article

Analysis of the NUPEC PSBT Tests with FLICA-OVAP

Table 8

Average absolute errors in steady-state DNB tests (%).

ā€‰1D Shah1D Katto
and Ohno
3D Shah3D Katto
and Ohno

Series 015.510.913.75.6
Series 213.516.012.318.3
Series 38.510.910.015.0
Series 414.814.613.719.1
Series 811.515.614.312.9
Series 134.816.44.619.6