Research Article
Validation of the Subchannel Code SUBCHANFLOW Using the NUPEC PWR Tests (PSBT)
Table 6
Boundary conditions for steady state bundle void fraction tests.
Pressure range (MPa)
4.8–16.6
Mass flux (kg/(m²s))
550–4170
Power (MW)
0.97–4.0
Inlet temperature (°C)
143–322