Journals
Publish with us
Publishing partnerships
About us
Blog
Science and Technology of Nuclear Installations
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
Science and Technology of Nuclear Installations
/
2012
/
Article
/
Tab 9
/
Research Article
Validation of the Subchannel Code SUBCHANFLOW Using the NUPEC PWR Tests (PSBT)
Table 9
Initial conditions for B7 transients.
Pressure (MPa)
15.5
Mass flux (kg/(m²s))
3300
Power (kW)
2500
Inlet temperature (°C)
291