Research Article
Numerical Study of the Steady-State Subchannel Test-Case with NEPTUNE_CFD for the OECD/NRC NUPEC PSBT Benchmark
Table 4
Cross-section averaged void fraction obtained on the three grid levels.
| ā | 1.2211 | 1.2223 | 1.2237 | 1.4325 | 1.4326 |
| Exp. values | 0.04 | 0.31 | 0.44 | 0.34 | 0.53 |
| Grid level 1 | 0.06 | 0.25 | 0.36 | 0.44 | 0.63 | Grid level 2 | 0.07 | 0.25 | 0.36 | 0.44 | 0.63 | Grid level 3 | 0.07 | 0.25 | 0.36 | 0.44 | 0.63 |
|
|