Research Article

Numerical Study of the Steady-State Subchannel Test-Case with NEPTUNE_CFD for the OECD/NRC NUPEC PSBT Benchmark

Table 8

Run 1.2211. Characteristics of the bubble-diameter at the measuring section with different modeling choices.

Average Minimum Maximum

Fixed bubble diameter 0.3 mm 0.3 mm 0.3 mm
Yao-Morel model 0.09 mm 0.005 mm 0.15 mm
Ruyer-Seiler model 0.15 mm 0.05 mm 0.2 mm