Numerical Study of the Steady-State Subchannel Test-Case with NEPTUNE_CFD for the OECD/NRC NUPEC PSBT Benchmark
Table 8
Run 1.2211. Characteristics of the bubble-diameter at the measuring section with different modeling choices.
Average
Minimum
Maximum
Fixed bubble diameter
0.3 mm
0.3 mm
0.3 mm
Yao-Morel model
0.09 mm
0.005 mm
0.15 mm
Ruyer-Seiler model
0.15 mm
0.05 mm
0.2 mm