Research Article
Accuracy and Uncertainty Analysis of PSBT Benchmark Exercises Using a Subchannel Code MATRA
Table 5
Optimum value of
at various operating conditions.
| Test number | (MPa) | (kg/m2s) | (°C) | Measured exit temperature (°C) |
Optimum | HH | HC | CH | CC |
| 01-1237 | 4.9 | 4722 | 86.0 | 174.6 | 170.0 | 155.8 | 147.7 | 0.072 | 01-5125 | 14.7 | 3038 | 289.2 | 330.3 | 327.5 | 322.7 | 319.3 | 0.081 | 01-5215 | 14.7 | 3041 | 282.9 | 335.6 | 334.5 | 328.0 | 322.4 | 0.084 | 01-5237 | 14.7 | 4708 | 229.4 | 299.6 | 294.6 | 287.8 | 280.7 | 0.089 | 01-5252 | 14.7 | 541 | 113.9 | 194.6 | 194.2 | 175.9 | 172.4 | 0.053 | 01-5342 | 14.7 | 533 | 164.5 | 260.1 | 256.9 | 244.7 | 239.8 | 0.080 | 01-5343 | 14.7 | 1397 | 165.3 | 257.9 | 252.9 | 242.4 | 235.5 | 0.093 | 01-6232 | 16.6 | 583 | 251.5 | 315.3 | 312.1 | 304.8 | 300.9 | 0.083 | 01-6233 | 16.6 | 1361 | 254.0 | 322.7 | 318.2 | 311.5 | 305.1 | 0.089 |
|
|