Research Article

Assessment of TRACE CCFL Model with SBLOCA Experiment of IIST Facility

Table 1

The comparison of major parameters between IIST facility and the Maanshan NPP.

ParameterIISTMaanshan PWRIIST/PWR

 Design pressure (MPa)2.115.6
 Maximum core power (MW)0.452775
 Primary system volume (m3)
 Number of loops331

Core
 Height (m)1.03.6
 Hydraulic diameter (m) 8.85
 Bypass area (m2)

Hot leg
 Inner diameter, (m)
 Length, (m)2.07.28
(m0.5)8.728.481.03

U-tube in one SG
 Number305626
 Average length (m)4.0816.85
 Inner diameter (mm)15.415.41.0
 Volume (m3) 18.44

Cold leg
 Inner diameter, (m)
 Length, (m)5.015.7
(m0.5)21.817.691.22

Downcomer
 Flow area (m2)0.01852.63
 Hydraulic diameter (m)

Pressurizer
 Volume (m3) 39.64
 Surge-line flow area (m2)