Analysis of Void Fraction Distribution and Departure from Nucleate Boiling in Single Subchannel and Bundle Geometries Using Subchannel, System, and Computational Fluid Dynamics Codes
Table 6
Mean absolute error of void fraction.
Code
Lower
Middle
Upper
Overall
FLICA4
Averaged error (%)
1.18
3.54
1.59
2.10
Mean absolute error (%)
2.95
5.29
4.04
4.09
TRACE
Averaged error (%)
9.54
7.45
3.35
6.78
Mean absolute error (%)
10.1
9.49
6.49
8.71