Research Article

PMK-2, the First Integral Thermal-Hydraulics Tests for the Safety Evaluation of VVER-440/213 Nuclear Power Plants

Table 8

Cladding temperatures in PHS-05, PHS-BF, and PH4-SLB tests.

IdentificationLocation rod. no./elevationPHS-05PHS-BFPH4-SLB
Break size 0.5%Break size 7.4%Break size 32%
—/mTime
s
Temp.
K
Time
s
Temp.
K
Time
s
Temp.
K

TE139/2.494479525.4238546.7
wall717543.4406851.4
1557470.6

TE146/2.994493551.2236553.4
normal733564.4419927.8
1578608.2

TE1511/3.4444768603.4525586.7224501.2
wall749572.7444821.4
1603685.7
TE161/3.4444768606.7520591.7223524.0
central749583.0444943.6
1603725.2

TE1716/3.4444767598.0512593.4223503.4
corner748586.4440882.0
1590667.7

TE182/3.4444768609.7525598.4224512.0
normal749584.4444913.0
1609725.4

TE193/3.4444768613.0520604.0224517.0
normal749591.4435916.0
1600717.0