Research Article

Evaluation of ASSERT-PV V3R1 against the PSBT Benchmark

Table 10

Number of cases where ASSERT steady state DNB predictions fell within of measured value, arranged by mass flux.

Mass flux (Mg/m2s) A0 A2 A3 A4 A8 A13 Total

7/12 5/10 6/10 18/32
8/10 7/12 5/10 16/21 17/22 4/4 57/79
6/9 8/10 9/15 6/6 16/16 34/36 79/92
28/41 26/33 18/24 31/32 34/38 20/20 157/188
6/10 7/9 6/8 7/7 7/7 33/41

Total 48/70 55/76 38/57 65/76 80/93 58/60 344/432