Research Article
Evaluation of ASSERT-PV V3R1 against the PSBT Benchmark
Table 10
Number of cases where ASSERT steady state DNB predictions fell within
of measured value, arranged by mass flux.
| Mass flux (Mg/m2s) | A0 | A2 | A3 | A4 | A8 | A13 | Total |
| | — | 7/12 | — | 5/10 | 6/10 | — | 18/32 | | 8/10 | 7/12 | 5/10 | 16/21 | 17/22 | 4/4 | 57/79 | | 6/9 | 8/10 | 9/15 | 6/6 | 16/16 | 34/36 | 79/92 | | 28/41 | 26/33 | 18/24 | 31/32 | 34/38 | 20/20 | 157/188 | | 6/10 | 7/9 | 6/8 | 7/7 | 7/7 | — | 33/41 |
| Total | 48/70 | 55/76 | 38/57 | 65/76 | 80/93 | 58/60 | 344/432 |
|
|