Research Article
Evaluation of ASSERT-PV V3R1 against the PSBT Benchmark
Table 8
Initial conditions and maximum rates of change for each of the experiments.
| | Pressure (MPa) | Mass flux (Mg/m2s) | Power (MW) | Inlet temperature (°C) |
| B5 | 15.0 | 3.3 | 2.3 | 300.1 | B6 | 15.4 | 3.3 | 2.6 | 288.5 | B7 | 15.5 | 3.3 | 2.5 | 291.5 | Max. rate | −0.03 MPa/s | −25%/s | +15%/s | 1°C/s |
|
|