Review Article
Integral Test Facility PKL: Experimental PWR Accident Investigation
Table 2
Measurement installation in PKL III (selection).
| | RPV | SG | Loops | Interfacing systems | PRZ | Total |
| Mass flow | 1 | | 14 | 64 | | 79 | Differential pressure | 9 | 18 | 20 | 8 | 3 | 58 | Fill level | 12 | 48 | 40 | 47 | 5 | 152 | Mass | | | | 3 | | 3 | Density | 10 | 2 | | 2 | 9 | 23 | Absolute pressure | 7 | 7 | 8 | 44 | 2 | 68 | Temperature | 286 | 345 | 182 | 158 | 29 | 1000 | Boron concentration | 16 | 4 | 32 | | 1 | 53 | Power measurement | 5 | 4 | 6 | 5 | 2 | 22 | Valve position [%] | | | | 68 | | 68 |
| Σ | | | | | | 1526 |
|
|