Research Article
CATHARE Assessment of Natural Circulation in the PKL Test Facility during Asymmetric Cooldown Transients
Table 4
Main events for PKL2 G2.1 Run-2.
| Time [s] | Measures/Events |
| 0 | Start of Run-2. Continuous cooldown initiated: continuous cooldown at 50°C/h by SG-2 and SG-4 | 80 | PRZ heater switched off | 2240 | Spraying in PRZ by volume control system switched on (positive subcooling in the SGU-tubes is maintained) | 6140 | Flow stagnation in loop-1 | 7310 | End of Run-2 |
|
|