Qualification of TRACE V5.0 Code against Fast Cooldown Transient in the PKL-III Integral Test Facility

Table 2

Post test: resulting sequence of main events.

#Event descriptionEXP (sec)GRNSPG UNIPI
TRACE5
Note

1Start of transient (break opening) in SG number 1 steam line00Imposed
2Heaters in SG number 1 switched off00Imposed
3Trip of the MCP and coastdown00Imposed
4PRZ heaters switched off00Imposed
5Butterfly valves closure210210Imposed
6MCPs completely stopped210210Imposed
7Affected SG level lower than <8.0 m6.49
8Affected SG level lower than <5.0 m32175
9Affected SG level lower than <2.5 m393422
10Affected SG level lower than <1.0 m579612
11Affected SG level lower than <0.1 m (emptied) 828819
12Affected SG pressure lower than <3.0 MPa10.410
13Affected SG pressure lower than <2.0 MPa4749
14Affected SG pressure lower than <1.0 MPa164177
15Affected SG pressure lower than <0.5 MPa435404
16Minimum PRZ level819806
17Minimum mass flow rate in loop 2 to 41060NA
18Minimum coolant temperature in CL number 1 (phase 1)525–565608
19Minimum core inlet temperature (phase 1)780–840867
20HPIS activated in loops number 1 and number 4 (0.2 kg/s)10301030Imposed
21Maximum temperature difference across SG number 1 (phase 1)380–420369
22PRZ safety valve 1st opening (steam released)1420 1378Steam discharged
23Water released through the PRZ safety valve 18401887
24End of calculation 44104410