Research Article
Assessment of CTF Boiling Transition and Critical Heat Flux Modeling Capabilities Using the OECD/NRC BFBT and PSBT Benchmark Databases
Table 5
Geometry and power shape for test assemblies A4 and A8 [
2].
| Item | Data | Assembly | | |
| Rods array | 5 × 5 | 5 × 5 | Number of heated rods | 25 | 24 | Number of thimble rods | 0 | 1 | Heated rod outer diameter (mm) | 9.50 | 9.50 | Thimble rod outer diameter (mm) | — | 12.24 | Heated rods pitch (mm) | 12.60 | 12.60 | Axial heated length (mm) | 3658 | 3658 | Flow channel inner width (mm) | 64.9 | 64.9 | Radial power shape | A | B | Axial power shape | Cosine | Cosine | Number of MV spacers | 7 | 7 | Number of NMV spacer | 2 | 2 | Number of simple spacers | 8 | 8 | MV spacer location (mm) | 471, 925, 1378, 1832, 2285, 2739, 3247 | NMV spacer location (mm) | 2.5, 3755 | Simple spacer location (mm) | 237, 698, 1151, 1605, 2059, 2512, 2993, 3501 |
|
|