Research Article

Uncertainty and Sensitivity Studies with TRACE-SUSA and TRACE-DAKOTA by Means of Steady State BFBT Data

Table 8

Sensitivity coefficients for the void fraction cases.

Case (4101-)Outlet pressureMass flow rateInlet temperatureWall roughness -spacerHydraulic diameterPower

04−0.159−0.2160.721−0.072−0.150−0.2050.461
−0.474−0.2390.640−0.052−0.0120.500
18−0.225−0.2050.651−0.071−0.120−0.2750.500
−0.415−0.2460.6560.0290.0120.567
29−0.250−0.2520.718−0.060−0.2100.0430.352
−0.476−0.2360.698−0.0390.0050.459
47−0.331−0.1140.8300.021−0.167−0.0240.213
−0.425−0.1850.8280.0100.0140.284
64−0.304−0.0180.8990.053−0.1620.0040.053
−0.450−0.0800.884−0.0060.0010.098
82−0.343−0.0590.8640.045−0.1670.0110.115
−0.502−0.1300.862−0.0160.0220.180