Research Article
Uncertainty and Sensitivity Studies with TRACE-SUSA and TRACE-DAKOTA by Means of Steady State BFBT Data
Table 8
Sensitivity coefficients for the void fraction cases.
| Case (4101-) | Outlet pressure | Mass flow rate | Inlet temperature | Wall roughness | -spacer | Hydraulic diameter | Power |
| 04 | −0.159 | −0.216 | 0.721 | −0.072 | −0.150 | −0.205 | 0.461 | −0.474 | −0.239 | 0.640 | −0.052 | −0.012 | — | 0.500 | 18 | −0.225 | −0.205 | 0.651 | −0.071 | −0.120 | −0.275 | 0.500 | −0.415 | −0.246 | 0.656 | 0.029 | 0.012 | — | 0.567 | 29 | −0.250 | −0.252 | 0.718 | −0.060 | −0.210 | 0.043 | 0.352 | −0.476 | −0.236 | 0.698 | −0.039 | 0.005 | — | 0.459 | 47 | −0.331 | −0.114 | 0.830 | 0.021 | −0.167 | −0.024 | 0.213 | −0.425 | −0.185 | 0.828 | 0.010 | 0.014 | — | 0.284 | 64 | −0.304 | −0.018 | 0.899 | 0.053 | −0.162 | 0.004 | 0.053 | −0.450 | −0.080 | 0.884 | −0.006 | 0.001 | — | 0.098 | 82 | −0.343 | −0.059 | 0.864 | 0.045 | −0.167 | 0.011 | 0.115 | −0.502 | −0.130 | 0.862 | −0.016 | 0.022 | — | 0.180 |
|
|