Research Article
CFD for Subcooled Flow Boiling: Parametric Variations
Table 3
Parameters used for the bubble detachment model.
| ā | (K) | (K) | (mm) |
| P26-G2-Q74-T16 | 359.5 | 0.1 | 0.247 | P26-G2-Q74-T18 | 359.2 | 0.35 | 0.237 | P26-G2-Q74-T20 | 359.0 | 0.62 | 0.228 | P26-G2-Q74-T26 | 356.4 | 3.23 | 0.165 | P26-G2-Q74-T28 | 351.6 | 8.03 | 0.154 |
| P26-G3-Q118-T16 | 359.3 | 0.3 | 0.152 | P26-G3-Q118-T20 | 358.5 | 1.1 | 0.152 | P26-G3-Q118-T24 | 355.9 | 3.7 | 0.134 | P26-G3-Q118-T28 | 352.5 | 7.1 | 0.124 |
| P26-G3-Q129-T29 | 353.8 | 5.8 | 0.142 | P26-G3-Q139-T28 | 355.7 | 3.9 | 0.163 | P26-G3-Q148-T28 | 356.4 | 3.3 | 0.161 |
|
|