Research Article

CFD for Subcooled Flow Boiling: Parametric Variations

Table 3

Parameters used for the bubble detachment model.

ā€‰ (K) (K) (mm)

P26-G2-Q74-T16359.50.10.247
P26-G2-Q74-T18359.20.350.237
P26-G2-Q74-T20359.00.620.228
P26-G2-Q74-T26356.43.230.165
P26-G2-Q74-T28351.68.030.154

P26-G3-Q118-T16359.30.30.152
P26-G3-Q118-T20358.51.10.152
P26-G3-Q118-T24355.93.70.134
P26-G3-Q118-T28352.57.10.124

P26-G3-Q129-T29353.85.80.142
P26-G3-Q139-T28355.73.90.163
P26-G3-Q148-T28356.43.30.161